RACELOGIC Traction Control Manual V3.0
Page 33
Read data
When ‘Read Data’ is selected, the software communicates with the traction
control connected via the serial port lead and reads out all the traction control
settings. These values are then displayed in the software.
Note: you cannot read from the unit whilst the ‘real time’ function is running.
Write Data
When ‘Write data’ is selected, all the settings shown in the software are
written into the unit connected via the serial lead.
Note: you cannot read from the unit whilst the ‘real time’ function is running.
Real Time Play / Stop
Selecting ‘Real Time play’ enables live data to be read from the traction
control. The ‘Real Time play’ button will be disabled and the ‘Real Time Stop’
button becomes available. Selecting ‘Real Time Stop’ will stop the unit
transmitting data.
An indication that data is being read from the traction control is the flashing
indicator in the top right corner of the screen.
The live data will be visible in the ‘Real Time’ tab and also the graph window.
You can also press the ‘F2’ key to start real time and ‘F3’ to stop real time
without entering the menu.